Mandeep Cables share a remarkable position in the market for bestowing the best quality of Cat-6 SFTP Cables to meet our client’s needs. Cables provided by Mandeep Cables are broadly used in different industries. We rely only on the finest quality of raw material which we source from the industry-renowned vendors to fulfill quality concerns of our clients. This category of networking cables is designed to accomplish industry-specified standards-based performance ensuring optimum bandwidth for today’s high-speed network applications. Furthermore, these have top notch quality and fine finishing. Moreover, these cables are available at affordable prices.
PRODUCT DESCRIPTION:
Enhanced performance cable for transmission of high speed data, digital and analogue voice and video (RGB) signals on LANs. Supports Gigabit Ethernet (1000 baseT) standard. Operates at bandwidth of 250 MHz. This cable well exceeds the requirements of TIA/EIA-568-C.2
Applications:
- ATM 622 or higher
- Broadband video (77 channels, 550MHz)
- 10 Base T (IEEE 802.3)
- 100 Base T (IEEE 802.3U)
- 100 Vg-Any LAN (IEEE 802.12) 4/16 Mbps Token ring (IEEE802.5)
- 100 Mbps TP-PMD
- 350 Mbps CDDI
- 1000 BASE-T gigabyte Ethernet
- ISDN,ADSL
Construction:
Conductor | Solid Bare Electrolytic Grade Copper |
Nominal Conductor Diameter | (24 AWG) |
Insulation | Polyolefin |
Color Code:
Pair #1 Pair #2 Pair #3 Pair #4 |
Orange-White with Orange stripe Brown-White with Brown stripe Blue-White with Blue stripe Green-White with Green stripe Pairs separated with a central slit film filler. |
Outer Jacket: | FR PVC |
Color of Outer Jacket | Grey / White |
Sequential Marking | At Every Meter |
Filler | Yes. Central Slit Film Cross Filler |
Thickness of Outer Jacket | 0.60mm nominal |
Approximate OD | 6.25mm |
Shielding #1 | Aluminium Mylar Tape with 100% coverage |
Shielding #2 | Wire Braid of Annealed Tinned Copper |
Earthling Link | Drain Wire of Annealed Tinned Copper |
L0W FREQUENCY ELECTRICAL PARAMETER
- CONDUCTOR RESISTANCE (DC): 9.38OHMS/100MTR@20 Degree C. MAX.
- RESISTANCE UNBALANCE : 5%MAX ? Dielectric Strength: 1.0KV DC or 0.75KV AC for i Min.
- Insulation Resistance: >500 M ohms km @ 500 VDC
- MUTUAL CAPACITANCE: 5.6 nF/100 mtrs Max.
- CAPACITANCE UNBALANCE PAIR/GROUND: 330PF/100M MAX
- Propagation Delay Skew: < 536 nS/100M
- Normal Velocity of Propagation: 69%
- IMPEDANCE: 100±15%OHMS
- Worst Case cable skew :< 45ns/100m
- Generally confirming to EIA/TIA 568-C and IEC/ISO 11801
HIGH FREQUENCY ELECTRICAL PARAMETER
FREQ | INS LOSS | NEXT Pair to Pair | NEXT power sum | ELFEXT Pair to Pair | ELFEXT Power Sum | ACR Pair to Pair | ACR Power sum | Return Loss |
---|---|---|---|---|---|---|---|---|
MHz | (dB/100m) | (dB/100m) | (dB/100m) | (dB/100m) | (dB/100m) | (dB/100m) | (dB/100m) | (dB/100m) |
min | min | |||||||
1 | 1.8 | 72 | 67.5 | 71.9 | 68.9 | 66.6 | 64.6 | 24.5 |
4 | 3.3 | 70.5 | 67 | 59.8 | 56.8 | 65 | 63 | 26.1 |
8 | 4.9 | 65.6 | 63 | 53.8 | 50.8 | 62 | 55.5 | 26.9 |
10 | 5.3 | 64 | 61.4 | 52 | 46.5 | 57.1 | 53.9 | 26.5 |
16 | 6.9 | 61 | 60.4 | 47.8 | 44.8 | 52 | 50.1 | 25.2 |
20 | 7.8 | 59.2 | 58.9 | 45.8 | 42.9 | 49.6 | 48 | 25 |
25 | 8.7 | 57.7 | 56.6 | 43.8 | 40.8 | 47 | 44.9 | 24.3 |
31.25 | 9.9 | 57.1 | 55.8 | 42 | 37.7 | 45.1 | 42.8 | 23.5 |
62.5 | 14.3 | 52 | 49 | 36 | 31.4 | 34.9 | 33.5 | 21.7 |
100 | 18.4 | 47 | 45.7 | 31.9 | 27.9 | 28.3 | 26 | 19.3 |
200 | 27.3 | 43.3 | 40.1 | 26 | 22 | 15 | 12.6 | 16.1 |
250 | 30.9 | 40.5 | 39.6 | 23.9 | 19.3 | 9.4 | 7.1 | 14.9 |
PACKAGING
305M –TANGLE FREE COIL
500M/ 1000M – Reel